Description
- 32-bit DSP digital control mode
- Low vibration, low noise, low power consumption
- Maximum output current 3A/phase
- Adopting CAN bus and supporting standard CANopen communication protocol, it can load up to 127 devices
- Supports three modes: protocol position control, speed control, and periodic position control
- Current setting, subdivision, motor start stop control, and real-time monitoring of motor operation can be achieved through the bus
- 2-channel optoelectronic isolation programmable input interface
medical equipment, various types of robots, robotic arms, automated production lines, and various CNC machine tools.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the elevator: V2 is the maximum speed of the elevator at this position.Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still 1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can be relatively improved, which is particularly important when the auxiliary shaft is lifted.2.2 Design and implementation of security protection functionsMines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures may occur, and detects the actions and feedback signals of these protection devices in real time.First of all, monitoring the operating status of the elevator is the top priority in the safety protection function of the elevator control system. In the control system, the operating speed and position of the motor are monitored at all times, and the current position and speed values are compared with the system”s designed speed and position curve. Once it is found that the actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire lifting process. At the same time, position detection switches are arranged at several locations in the wellbore, and these position detection switches correspond to specific position values and corresponding speed values. When the elevator passes these switches, if it is found through encoder detection that the actual speed value and position deviate from the values corresponding to the position detection switch, the control system will also judge that it is in a fault state and immediately implement an emergency stop.In order to determine whether the encoder connected to the main shaft of the elevator drum is normal, two other encoders are installed on the elevator. In this way, the position and speed detection values of the three encoders are always compared. Once it is found that the deviation between the detection value of one encoder and the detection value of the other two encoders exceeds the allowable range, the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.3 ConclusionThe efficient and safe operation of main well equipment is an important guarantee for its function. In the application of mine hoist, the 800xA system designed speed curve, self-correction, various self-diagnosis and protection functions according to the specific process characteristics of the main shaft mine hoist, which has achieved good results in practical applications.
XV-152-D6-84TVRC-10 Human Machine Interaction
XN-QV/1 Intelligent operation control system
MK2-252-57MPN-1-10 Human Machine Interaction
XV-303-15-C00-A00-01 Human Machine Interaction
XV-102-B4-35TQRF-10 EATON Touch Panel
XVC-601-GTI-12-DPS-V1-000 Human Machine Interaction
MK2-252-57CNN-1-10 Capacitive touch screen and resistive touch screen
XN-P4T-SBBC-B EATON Touch Panel
XV-430-10TVB-1-10 Capacitive touch screen and resistive touch screen
OS-FLASH-A1-L Intelligent operation control system
XVH-340-57BAS-1-10 Human Machine Interaction
MC2-442-57CQB-1-10 EATON HMI Human Machine Interface
STARTERKIT-XV100-PLC-CAN-RS232 Intelligent operation control system
MC2-442-57CQB-1-2O Eaton human-machine touch screen
XV-440-10TVB-1-1ABVAR02 Eaton human-machine touch screen
XCC-601-DVI-DPS-V1-000 Intelligent operation control system
XN-KO/17 Eaton human-machine touch screen
OS-FLASH-A1-L Eaton human-machine touch screen
XP-DVI-10T-10 Human Machine Interaction
XN-B6T-SBCSBC EATON Touch Panel
MC2-430-10TVB-1-11 Capacitive touch screen and resistive touch screen
DPM-MC2 Eaton human-machine touch screen
XV-102-D0-70TWR-10 Intelligent operation control system
XN-PF-120/230VAC-D EATON Touch Panel
XP-301-10T-10 EATON HMI Human Machine Interface
MTL831C Eaton human-machine touch screen
XV-303-70-B00-A00-1B Eaton human-machine touch screen
XVS-440-10MPI-1-1AD Intelligent operation control system
XV-102-B2-35TQR-10 Eaton human-machine touch screen
XN-GWBR-CANOPEN EATON Touch Panel
STARTERKIT-XV100-PLC-CAN-RS485-EC4E EATON Touch Panel
XV-230-57MPN-1-10 EATON Touch Panel
MC2-442-57CQB-1-10 Eaton human-machine touch screen
MC2-440-10TVB-1-20 Capacitive touch screen and resistive touch screen
xvs-440-10mpi-1-1u EATON Touch Panel
XV-152-D0-57TVR-10 Eaton human-machine touch screen
XN-PF-120/230VAC-D Human Machine Interaction
XV-363-57-C02-A00-1B EATON HMI Human Machine Interface
XV-252-57CNN-1-10-PLC-SET Capacitive touch screen and resistive touch screen
XVC-601-GTI-15-DPM-V1-000 EATON HMI Human Machine Interface