Description
- 32-bit DSP digital control mode
- Low vibration, low noise, low power consumption
- Maximum output current 3A/phase
- Adopting CAN bus and supporting standard CANopen communication protocol, it can load up to 127 devices
- Supports three modes: protocol position control, speed control, and periodic position control
- Current setting, subdivision, motor start stop control, and real-time monitoring of motor operation can be achieved through the bus
- 2-channel optoelectronic isolation programmable input interface
medical equipment, various types of robots, robotic arms, automated production lines, and various CNC machine tools.
5 Fieldbus network layer5.1 mfb (master field bus) busThe mfb bus is a field LAN bus and is connected between mp200, mp90, s400i/o, OPC (small control station) and the transmission system. The mfb communication bus uses coaxial cables and twisted pairs. It connects the ci520/ci525/ci526 communication interface module and the dstc452 modem. The ends of each twisted pair must be isolated, and the shielding layer of one end must be grounded. The communication of mfb The rate is 375kb/s, its resistance is 75 ohms, and its hardware configuration is shown in Figure 3. The relevant system information of mfb is obtained from the engineering station. The general order is time, information model, code, task number, sequence number, and data. It mainly displays the following states.Code 20: cpu communication interface contact lostCode 21: fatal hardware failureCode 39: device/staTIon okCode 72: device/statIon address okCode 120: Process failureCode-1: Execution errorCode -4: System errorCode -5: Minor system site errorCode-6: Communication failureCode-9: Catastrophic bus failureCode -10: Redundant cable interrupted5.2 af100 (advant field)/mb90 (master bus) busThe purpose of AF100/MB90 is to provide communication between multiple APC sites or between APC sites and ABB industrial system equipment. MB90 supports two different types of communication, data processing and information sending. The data set is dynamic data. Use To monitor and control a certain processing process, this process uses service information for parameterization, program installation, and diagnosis. AF100/MB90 is a high-performance regional bus capable of connecting up to 79 APC sites. The mb90 has a maximum length of 300 meters, and if equipped with appropriate signal cables and signal repeaters, and long-distance configurations between individual transmission devices are available, up to 2000 meters. Technical characteristics of the bus(1) Communication rate 1.5mbit/s(2) Attenuation bus length <300m, proliferation delay <2000m(3) Telegram length 2, 4, 6, 8,…32 bytes of user data.(4) Identification code (telegraph code) range 1…4000(5) Cycle time 2, 4, 8, 16, 32, 64, 128…2048 or 4096msaf100/mb90 relies on a centralized bus manager. The bus manager functions are relatively complex and have many requirements. For example, apc sites cannot be used as bus managers because they do not contain bus manager functions. To make communication between APCs via AF100/MB90 possible, each solution (standalone and embedded) can be used to arrange the bus master of AF100/MB90. When the APCs start executing their applications, the bus master must be operable, otherwise the data set function block within the apc branch will enter an error state when the locally configured data set is not acknowledged by the bus manager within the specified time limit. , if the system has only apc site and no masterpiece is connected to mb90 or ac450 and af100, an independent bus manager should be installed.The communication between ABB DCS and the transmission system (such as acv700/dcv700) is realized by relying on the drrtra (drive trans mi t) element and drrec (drive reciver) element shown in Figure 4 .The drrtra (drive transmit) element is used to pass a given data set to the abb drive controller and select the control word and command word signal of the drive signal. The definition of the control word and command word signal is given in the application drive software description. The drrtr element can generate different types of periodic messages supported by the drive communication protocol. The destination of the signal is selected by the drive signal. The drrtr element can also write parameters. In the normal phase, the overload of drrtr can be detected.The drrec (drive reciver) element is used to receive signals and control word values from the abb drive controller. The definitions of these signals are given in the application drive software description. The drrec element is just periodic information supported by the drive connection protocol. The receiving data source is selected by determining the drive signal and signal index through the element input parameters. The drrec element also has access to parameters, and overloads of drrec can be detected during configuration.
XV-460-57TQB-1-10 Intelligent operation control system
XVM-410-65TVB-1-11 Human Machine Interaction
XN-QV/4 Human Machine Interaction
XV-442-57CQB-1-30 Intelligent operation control system
XVS-440-10MPI-1-1U Intelligent operation control system
XV-252-57CNN-1-1K Intelligent operation control system
XN-P3T-SBB-B Eaton human-machine touch screen
XV-440-10TVB-1-13 Human Machine Interaction
MS2-430-12MPI-1-10 EATON HMI Human Machine Interface
XN-KO/2 Human Machine Interaction
MEMORY-CF-A7-S Eaton human-machine touch screen
XVH-340-57MPI-1-1Q Eaton human-machine touch screen
XV-102-B4-35TQR-10-PLC EATON Touch Panel
XP-DVI-15T-10 EATON Touch Panel
XV-252-57CNN-1-10-PLC EATON HMI Human Machine Interface
XVS-460-84MPI-1-10 Eaton human-machine touch screen
OS-FLASH-A3-S Capacitive touch screen and resistive touch screen
SW-EPAM EATON Touch Panel
XVH-340-57MPI-1-10 Capacitive touch screen and resistive touch screen
XN-S4T-SBBS EATON HMI Human Machine Interface
XN-32DO-24VDC-0.5A-P Eaton human-machine touch screen
XV-230-57MPN-1-10(OS/CF) Capacitive touch screen and resistive touch screen
XV-152-D8-84TVR-10 EATON Touch Panel
XV-440-10TVB-1-1ABVAR02 EATON Touch Panel
XV-252-57CNN-1-1KVAR08 EATON Touch Panel
MC2-442-57CQB-1-2G Eaton human-machine touch screen
XN-B4S-SBBC Intelligent operation control system
XNE-8DI-24VDC-P Intelligent operation control system
xv-440-10tvb-1-20 Human Machine Interaction
XV-102-B5-35TQR-10-PLC EATON HMI Human Machine Interface
XV-432-57CQB-1-10-PLC-SET Capacitive touch screen and resistive touch screen
XVH-340-57CAN-1-50 EATON Touch Panel
XN-S4T-SBBC Intelligent operation control system
XN-QV/1 Capacitive touch screen and resistive touch screen
MS2-440-12MPI-1-10 Capacitive touch screen and resistive touch screen
MC2-442-57CQB-1-1D Intelligent operation control system