Description
- 32-bit DSP digital control mode
- Low vibration, low noise, low power consumption
- Maximum output current 3A/phase
- Adopting CAN bus and supporting standard CANopen communication protocol, it can load up to 127 devices
- Supports three modes: protocol position control, speed control, and periodic position control
- Current setting, subdivision, motor start stop control, and real-time monitoring of motor operation can be achieved through the bus
- 2-channel optoelectronic isolation programmable input interface
medical equipment, various types of robots, robotic arms, automated production lines, and various CNC machine tools.
In the formula, a is the design acceleration/deceleration value: s is the current actual position value of the elevator: V2 is the maximum speed of the elevator at this position.Considering that the lifting system needs to enter the parking track at a low crawling speed when entering the end of the stroke to avoid equipment damage caused by large mechanical impact, therefore, when there are still 1~5m away from the parking position, the lifting speed is limited to 0.5m/ below s.Since the instantaneous speed before parking is very low, the position accuracy of the system”s parking can be relatively improved, which is particularly important when the auxiliary shaft is lifted.2.2 Design and implementation of security protection functionsMines have particularly strict requirements on safety and reliability of hoist control systems [5]. While ensuring high reliability of electrical control equipment, the control system also sets up multiple protections in key links where failures may occur, and detects the actions and feedback signals of these protection devices in real time.First of all, monitoring the operating status of the elevator is the top priority in the safety protection function of the elevator control system. In the control system, the operating speed and position of the motor are monitored at all times, and the current position and speed values are compared with the system”s designed speed and position curve. Once it is found that the actual operating speed of the hoist exceeds the designed speed value, immediately Issue an emergency stop command and strictly ensure that the lifting speed is within the safe monitoring range during the entire lifting process. At the same time, position detection switches are arranged at several locations in the wellbore, and these position detection switches correspond to specific position values and corresponding speed values. When the elevator passes these switches, if it is found through encoder detection that the actual speed value and position deviate from the values corresponding to the position detection switch, the control system will also judge that it is in a fault state and immediately implement an emergency stop.In order to determine whether the encoder connected to the main shaft of the elevator drum is normal, two other encoders are installed on the elevator. In this way, the position and speed detection values of the three encoders are always compared. Once it is found that the deviation between the detection value of one encoder and the detection value of the other two encoders exceeds the allowable range, the control system will immediately consider it to have entered a fault state and implement an emergency stop. Protective action.3 ConclusionThe efficient and safe operation of main well equipment is an important guarantee for its function. In the application of mine hoist, the 800xA system designed speed curve, self-correction, various self-diagnosis and protection functions according to the specific process characteristics of the main shaft mine hoist, which has achieved good results in practical applications.
XNE-GWBR-CANOPEN EATON ELECTRIC Touch panel
XV-252-57MPN-1-10-PLC Eaton Display Screen
XVS-460-84MPI-1-10 EATON ELECTRIC Touch panel
XV-152-D6-10TVR-10 EATON ELECTRIC Touch panel
XVC-601-GTI-10-DPM-V1-000 Micro Innovation touch
XNE-GWBR-ETH-SL Touch Screen Glass for HMI
XV-440-10TVB-1-2I 139969 eaton touchscreen
XV-460-57TQB-1-10 Industrial Control Panel eaton
XNE-16DI-24VDC-P Touch Screen Glass for HMI
XN-4DI-24VDC-N Touch Screen Glass for HMI
XV-102-B0-35TQR-10-PLC Industrial Control Panel eaton
XV-112-DB-70TWRC-00 EATON ELECTRIC Touch panel
XV-252-57MPN-1-1AH Micro Innovation touch
xv-102-b5-35-tqr-10-plc 139969 eaton touchscreen
XV-442-57CQB-1-50 Industrial Control Panel eaton
MC2-442-57CQB-1-1F 139969 eaton touchscreen
OS-FLASH-A1-C Touch Screen Glass for HMI
XVC-601-GTI-15-DPM-V1-000 Touch Screen Glass for HMI
XNE-GWBR-CANOPEN Eaton Display Screen
XN-S4S-SBBC EATON ELECTRIC Touch panel
XN-LABEL/BLOCK Touch Screen Glass for HMI
XN-KO/1 Eaton Display Screen
XV-430-12TSB-1-10 139969 eaton touchscreen
XV-DVI-GTI-12-000 Touch Screen Glass for HMI
XVS-430-10MPI-1-10 Industrial Control Panel eaton
XVC-101-C192K-K82-1AA Industrial Control Panel eaton
XV-102-D6-70TWR-10 139969 eaton touchscreen
STARTERKITECOSYSTEMDP Eaton Display Screen
XN-4DI-24VDC-N Eaton Display Screen
XV-102-B5-35MQR-10-PLC Industrial Control Panel eaton
XV-460-84TVB-1-1O 139969 eaton touchscreen
XN-2DO-120/230VAC-0.5A Industrial Control Panel eaton
XN-KO/9 EATON ELECTRIC Touch panel
MC2-440-10TVB-1-1D Eaton Display Screen
XN-PLC-CANOPEN Eaton Display Screen
MC2-442-57CQB-1-21 Eaton Display Screen
XN-KO/1 Micro Innovation touch
XN-KO/11 EATON ELECTRIC Touch panel
XP-DVI-15T-10 Eaton Display Screen
XVS-450-57MPI-1-10 Eaton Display Screen
XN-KO/13 EATON ELECTRIC Touch panel
XVS-430-10MPI-1-1AC Touch Screen Glass for HMI