Description
1D54561G02 Emerson Ovation HART Analog Output Module
thereby controlling external devices or circuits.
The main power supply of the fire linkage controller generally uses 220V AC voltage; The backup power source is a DC power source, powered by batteries, with a supply voltage of generally 24-32V. When powered by AC, the grid voltage is between 85% and 110% of the rated voltage (220V).
When the frequency fluctuates within the range of 50Hz ± 1Hz, the fire linkage controller should be able to work normally. The voltage stability and load stability of its output DC voltage shall not exceed 5%.
3) Electromagnetic compatibility:
The electromagnetic compatibility of the fire linkage controller refers to the adaptability and stability of the fire linkage controller under electromagnetic interference environmental conditions, which should comply with the relevant provisions of the current national standard GB16806 “Fire Linkage Control System”.
4) Security performance:
The safety performance of the fire linkage controller refers to the electrical safety performance of the fire linkage controller in use, which should comply with the relevant provisions of the national standard GB16806 “Fire Linkage Control System”.
3、 Engineering application
The engineering design, construction, and acceptance of the fire linkage controller shall comply with the relevant provisions of the current national standards GB50116 and GB50166. In terms of selection and use,
cabinet, desktop, and wall mounted fire linkage controllers should be selected according to the characteristics of the usage location, system scale, and user needs. Wall mounted fire linkage controllers are commonly used in small and medium-sized fire linkage control systems; For large-scale or ultra large scale fire linkage control systems, cabinet or desktop fire linkage controllers should be selected. Corresponding forms of fire linkage controllers should also be selected based on the usage
environment conditions and certain special requirements. Explosion proof fire linkage controllers should be selected for environments that are prone to explosion hazards; Marine fire linkage controllers should be selected for marine use.
responsible for processing signals from on-site sensors or driving actuator actions. For example, they may need to cooperate with devices such
as BANNER travel switch T30UIPB to receive their transmitted position signals; Or by controlling components such as Burkert solenoid valve 00131421, the on/off of fluid media can be precisely managed.
these modules integrate more complex logic processing capabilities. The core task of a pressure switch is to detect whether the pressure
has reached a preset threshold and output a switch signal. Its function is highly specific and fixed. And modules 1D54561G02 and 1
C31219G01 have the ability to comprehensively judge multiple such switch signals and transmitter signals (such as transmitter 1066-P-HT-60),
and output complex control instructions according to internal logic.