1. Function
1) The fire linkage controller can receive fire alarm signals from the fire alarm controller and emit fire alarm sound and light signals. In a non delayed state, it can send a start signal to various controlled devices connected to it within 3 seconds, directly or indirectly control the controlled device according to the set control logic, and at the same time send a start light indication signal. The fire linkage controller can receive feedback signals from controlled equipment actions and display the corresponding equipment status.
2) The fire linkage controller can receive alarm signals from related triggering devices such as the pump start button, water flow indicator, and gas fire extinguishing system start button, display their location, emit alarm sound and light signals, and send the alarm signals to the connected fire alarm controller.
3) The fire linkage controller can complete all control functions and indicate status manually or automatically. In automatic mode, manual insertion operation takes priority.
4) The fire linkage controller has a direct manual control unit. The direct manual control unit shall have at least six independent manual control switches, each corresponding to a direct control output. When the direct manual control unit can be used independently, various working states such as startup and feedback of the controlled equipment can be displayed separately next to the manual control switch. When the direct manual control unit cannot be used independently, the other working states of the controlled equipment, except for the startup state, are indicated separately next to the manual control switch or displayed on the shared display of the linkage controller.
5) The fire linkage controller can initiate logical relationships through manual or programmed input, and has corresponding input “OR” logic and/or “AND” logic programming functions for control outputs.
responsible for processing signals from on-site sensors or driving actuator actions. For example, they may need to cooperate with devices such
as BANNER travel switch T30UIPB to receive their transmitted position signals; Or by controlling components such as Burkert solenoid valve 00131421, the on/off of fluid media can be precisely managed.
these modules integrate more complex logic processing capabilities. The core task of a pressure switch is to detect whether the pressure
has reached a preset threshold and output a switch signal. Its function is highly specific and fixed. And modules 1C31129G04 and 1
C31219G01 have the ability to comprehensively judge multiple such switch signals and transmitter signals (such as transmitter 1066-P-HT-60),
and output complex control instructions according to internal logic.