DS200CTBAG1A Processor/Controller Mark VI System

Brand: GE

model: DS200CTBAG1A
System: Gas turbine system
Origin: United States

The GE DS200CTBAG1A turbine control module is used for various applications, including:

Electric power generation

Oil and Gas

EADS

ship

  • Email:sauldcsplc@outlook.com
  • Phone:+86 18350224834
  • WhatsApp:+8618350224834

Description

DS200CTBAG1A Product Introduction

GE DS200CTBAG1A Embedded Controller Module
 
GE DS200CTBAG1A Embedded Controller Module Product Details:
 
GE DS200CTBAG1A is an embedded controller module developed by General Electric (GE) for industrial automation and control systems.
The specific application scope of the product
will depend on the needs of system integration and industrial application, but generally speaking, this type of embedded controller module can be applied to the following categories:
 
Industrial automation: used to master and monitor various automation processes in the factory, such as production lines, machine installation,
manufacturing processes, etc.
Power industry: used for mastering and monitoring tasks in power plants and power distribution systems.
Chemical and process industries: used to monitor and grasp the production process in chemical plants, refineries, and other process industries.
Manufacturing industry: can be used to master and optimize the production process, ensuring the effectiveness of labor and product quality.
Transportation: The application in the traffic signal system, railway system, or other traffic control systems.
Construction automation: used for automation systems in construction, such as building management systems, intelligent construction control systems, etc.
Fire disposal punishment and situation control: application in the pollution fire disposal punishment plant, fire disposal punishment measures, and situation
monitoring and control system.
These are just some potential application areas, in fact, there can be more application scenarios, depending on the effectiveness and personality
of the controller module, as well as the specific needs of the customer.
 
 
General Electric has designed the processor/controller for the DS200CTBAG1A Mark VIe system. The Mark VI platform is General Electric”s Speedtronic range,
designed to manage gas or steam turbines.
It has a CIMPLICITY graphical interface and an HMI with software suitable for running heavy-duty turbines.
 
 
This DS200CTBAG1A is a single box assembly with a front panel for communication connections, two screws installed on the rear edge, and three grille holes for ventilation. The controller is designed to
be installed at the bottom of the cabinet. For a small setup that is easy to serve a triple redundant system, up to three components can be installed side by side.
 
DS200CTBAG1A uses the QNX operating system. It has a 667MHz Freescale 8349 processor. This board is powered by a 12 watt, 18-36 V DC power supply. Even at its maximum rated temperature, t
he board can operate within a temperature range of 0 to 65 degrees Celsius without the need for a fan for cooling. NFPA Class 1. This board can be used for two applications.
Contact Us
 
Mobile phone: 18350224834
 
E-mail: sauldcsplc@outlook.com
 
WhatsApp:+86 18350224834

3.3 Design of computer control softwareThis type of control software runs on the computer and is mainly used for remote operation. It has multiple functions such as parameter setting, control operation, data collection and storage, status detection and alarm, etc. Its interface is shown in Figure 3.The system shown in Figure 3 contains four independent control channels, and the software can manage and configure the test plan based on parameter information. That is: for each test plan, you can configure different test plans and set different test parameters through the “Configuration” operation. You can also create new plans, save and modify plans, open existing plans, and delete plans.The software also sets up quick operations, which can quickly start and stop work according to the channel configuration, and can detect the working status of each channel in real time.3.4 Design of touch screen softwareThe touch screen software is mainly used for local control and runs in the touch screen controller. While the computer control software has similar functions, it also has the setting function of local control priority or remote control priority. The default is remote control priority. The login interface and test operation interface are shown in Figure 4 and Figure 5 respectively.3.5 Design of PLC softwareAs the core of this control system, PLC is mainly responsible for the following aspects:Responsible for sending corresponding control parameters and instructions to the frequency converter, and at the same time obtaining the status of the transmission system through the ProfibusDP bus protocol.Communicates with the touch screen through serial communication, responds to local control instructions, and feeds back system status to the touch screen as a slave computer for local control. Programming between the touch screen and PLC is performed by directly accessing the PLC variable address.It communicates with the remote control computer through the OPC[5] communication method based on the external network, responds to the remote control instructions, and feeds back the system status to the remote control computer as the remote control slave. Programming between the remote control program and the PLC is performed by accessing the PLC variable name.Process the emergency signal and control the inverter to slow down and unload according to the default parameters.Figure 4 Login interfaceFigure 5 Test interface3.6 Frequency converter settingsIn general, the inverter will be equipped with an optional operation panel. Before using the local or remote control program to operate the inverter, you must first perform the basic settings of the inverter, as follows:Switch the control mode to local control and set the inverter address according to the inverter user manual.Set the inverter for remote control and select the communication mode.Set the frequency converter to use an encoder, and connect the motor for self-test matching operation.Set the speed control mode of the inverter, such as speed control or torque control.After completing the basic parameter settings, switch to the remote control state and wait for remote control.4 ConclusionThis system implements a universal belt-turning mechanism that utilizes frequency conversion control technology. You can use the local touch screen to control the inverter to control the motor rotation and obtain corresponding feedback, or you can use remote control to control the inverter to achieve the same control effect as the local touch screen, even in view of the computer function The richness allows you to obtain more system information and set more control states. In addition to local touch screen control and remote control, the overall structure of this system can also be split into the most basic transmission structure to complete the control, that is, the motor is controlled directly through the control panel of the frequency converter to achieve the most basic and direct control. Therefore, this system can be used as a basic framework structure to meet all similar control requirements, and obtain different levels of usage requirements through different levels of hardware configuration, which has universal reference significance.

IS215UCVFH2AB Processor/Controller Mark VI System
DS200FCSAG1ACB Processor/Controller Mark VI System
IS200EXCSG1A GE power control board
IS200TDBSH2A I/O excitation redundant module GE
IS420YVIBS1B Processor/Controller Mark VI System
IS200HSLAH2A Processor/Controller Mark VI System
IS215UCVFH2AB Gas turbine system Mark VI
IS210AEPSG1B GE power control board
DS200SPCBG1ADC High performance processor module GE
IS210DRTDH1AA Gas turbine system Mark VI
IS420ESWBH3AX GE power control board
IS230SNAIH4A I/O excitation redundant module GE
IS200VTURH1BAC From General Electric in the United States
IS420ESWBH3A From General Electric in the United States
DS2020FEXAG4 I/O excitation redundant module GE
IS200ACLEH1ABA GE power control board
IS200BICIH1ADB Gas turbine system Mark VI
IS200PMCIH1AAA6BA00 GE power control board
IS200IGPAG2A I/O excitation redundant module GE
DS200RTBAG1AHC Processor/Controller Mark VI System
DS200PCCAG9ACB From General Electric in the United States
DS200RCIAG1AAA GE power control board
IS200TBCIH2C GE power control board
DS3800XPEX1B1A I/O excitation redundant module GE
IS215UCCAM03A GE power control board
DS200PCCAG6A Gas turbine system Mark VI
IS410JPDDG2A From General Electric in the United States
IS220PDIOH1A Gas turbine system Mark VI
DS200ADMAH1AAC Gas turbine system Mark VI
IS200EHPAG1B From General Electric in the United States
IS200AEBMG1AFB GE power control board
DS200VPBLG1AEE From General Electric in the United States
IS200JPDDG1AAA I/O excitation redundant module GE
IS200EXHSG4A Gas turbine system Mark VI
DS200DMCAG1AJD I/O excitation redundant module GE
DS200PCCAG6A Processor/Controller Mark VI System
IS420PSCAH1B Gas turbine system Mark VI
IS200DTAOH1ABA Gas turbine system Mark VI
IS200BPVCG1B Gas turbine system Mark VI
IS200EDCFG1A I/O excitation redundant module GE
DS200DTBAG1AAA Gas turbine system Mark VI
DS215TCQAG1BZZ01A Gas turbine system Mark VI
DS200SHCAG1B From General Electric in the United States
IS420ESWAH5A From General Electric in the United States
IS200TREGH1BDB I/O excitation redundant module GE
IS200ERRRH1A Processor/Controller Mark VI System
IS200VSCAH2A From General Electric in the United States
IS200TBAIH1B Processor/Controller Mark VI System
IS200IHG1A Gas turbine system Mark VI
IS200ADIIH1AAA Gas turbine system Mark VI
DS200TCQCG1BLG I/O excitation redundant module GE
IS215VCMIH2CA Gas turbine system Mark VI
IS200IGDMH1B Gas turbine system Mark VI
DS200DTBDG1ABB I/O excitation redundant module GE
IS200TTPWH1A Gas turbine system Mark VI
IS200TBAIH1C From General Electric in the United States
IS200VPROH2B I/O excitation redundant module GE
IS220PAISAH1A Processor/Controller Mark VI System
IS220PDIIH1B From General Electric in the United States
IS220PPDAH1A Gas turbine system Mark VI
IS200JGNDG1A High performance processor module GE
IS200VAICH1DAB I/O excitation redundant module GE
DS200GGXCG1A I/O excitation redundant module GE
IS200TBTCH1CBB I/O excitation redundant module GE
IS220PTURH1A I/O excitation redundant module GE
IS230STTCH2A I/O excitation redundant module GE
DS200DTBDG1 Gas turbine system Mark VI
IS200PTURH1B Gas turbine system Mark VI
IS215VCMIH2B High performance processor module GE
DS3820LT4AICIA Gas turbine system Mark VI
IS215PMVPH1A Processor/Controller Mark VI System
IS200DSPXH2DBD From General Electric in the United States
DS200SLCCG3ACC From General Electric in the United States
IS200PTURH1B High performance processor module GE
GE DS200EXPSG1A Processor/Controller Mark VI System
IS200ERDDH1 High performance processor module GE
IS200TVIBH2BBB GE power control board
DS200TCQAG1A GE power control board
IS210BPPBH2BMD Gas turbine system Mark VI
IS200TDBTH6A Processor/Controller Mark VI System
IS200EPBPG1ACD Processor/Controller Mark VI System
DS200DSFBG1A From General Electric in the United States
DS200PCCAG10A Gas turbine system Mark VI
DS200FSAAG2ABA I/O excitation redundant module GE
IS210AEBIH1ADC Gas turbine system Mark VI
IS220PSVOH1A From General Electric in the United States
DS200ADPBG1A From General Electric in the United States
DS200TCPDG1BEC I/O excitation redundant module GE
DS200TCDAH1B Gas turbine system Mark VI
IS200WNPSH1ABA Gas turbine system Mark VI
IS420UCSBS1A Gas turbine system Mark VI
IS420ESWBH2A From General Electric in the United States
IS200ERSCG1A I/O excitation redundant module GE
IS200ESELH1A GE power control board
DS200TCRAG1A GE power control board