Description
5437-092 WOODWARD Speed Sensor Full Series
Non differential regulation is mainly used for constant speed control and is suitable for single machine operation or multiple prime movers working together in an isolated power grid. Differential regulation provides more control flexibility.
further enhancing its performance and application range.
rich additional functions, and high-precision output signals. Whether it is in the fields of generator sets, compressors, pump stations, or ships and locomotives, it can effectively ensure the stable operation of equipment within the set range.
power measurement level 1, editable screen, multi interface toolkit connection, etc. All details can be found in Woodward easyYgen manual 37582A
The rated operating temperature range of this model is -20 to 70 ° C; the rated temperature range of the LT model is -40 to 70 ° C, suitable for outdoor use.
5437-092 is equipped with a monitor (not available on the 3100 model) and is designed for front panel installation.
The built-in HMI has a color LCD and soft keys (now with dedicated buttons) for direct control of the 5437-092 device. Multi level password protection can prevent unauthorized changes.
The generator set has four operating modes and the option to configure a manual circuit breaker control device.
How to use 5437-092?
What is 5437-092 used for?
5437-092 Customs Code
5 Fieldbus network layer5.1 mfb (master field bus) busThe mfb bus is a field LAN bus and is connected between mp200, mp90, s400i/o, OPC (small control station) and the transmission system. The mfb communication bus uses coaxial cables and twisted pairs. It connects the ci520/ci525/ci526 communication interface module and the dstc452 modem. The ends of each twisted pair must be isolated, and the shielding layer of one end must be grounded. The communication of mfb The rate is 375kb/s, its resistance is 75 ohms, and its hardware configuration is shown in Figure 3. The relevant system information of mfb is obtained from the engineering station. The general order is time, information model, code, task number, sequence number, and data. It mainly displays the following states.Code 20: cpu communication interface contact lostCode 21: fatal hardware failureCode 39: device/staTIon okCode 72: device/statIon address okCode 120: Process failureCode-1: Execution errorCode -4: System errorCode -5: Minor system site errorCode-6: Communication failureCode-9: Catastrophic bus failureCode -10: Redundant cable interrupted5.2 af100 (advant field)/mb90 (master bus) busThe purpose of AF100/MB90 is to provide communication between multiple APC sites or between APC sites and ABB industrial system equipment. MB90 supports two different types of communication, data processing and information sending. The data set is dynamic data. Use To monitor and control a certain processing process, this process uses service information for parameterization, program installation, and diagnosis. AF100/MB90 is a high-performance regional bus capable of connecting up to 79 APC sites. The mb90 has a maximum length of 300 meters, and if equipped with appropriate signal cables and signal repeaters, and long-distance configurations between individual transmission devices are available, up to 2000 meters. Technical characteristics of the bus(1) Communication rate 1.5mbit/s(2) Attenuation bus length <300m, proliferation delay <2000m(3) Telegram length 2, 4, 6, 8,…32 bytes of user data.(4) Identification code (telegraph code) range 1…4000(5) Cycle time 2, 4, 8, 16, 32, 64, 128…2048 or 4096msaf100/mb90 relies on a centralized bus manager. The bus manager functions are relatively complex and have many requirements. For example, apc sites cannot be used as bus managers because they do not contain bus manager functions. To make communication between APCs via AF100/MB90 possible, each solution (standalone and embedded) can be used to arrange the bus master of AF100/MB90. When the APCs start executing their applications, the bus master must be operable, otherwise the data set function block within the apc branch will enter an error state when the locally configured data set is not acknowledged by the bus manager within the specified time limit. , if the system has only apc site and no masterpiece is connected to mb90 or ac450 and af100, an independent bus manager should be installed.The communication between ABB DCS and the transmission system (such as acv700/dcv700) is realized by relying on the drrtra (drive trans mi t) element and drrec (drive reciver) element shown in Figure 4 .The drrtra (drive transmit) element is used to pass a given data set to the abb drive controller and select the control word and command word signal of the drive signal. The definition of the control word and command word signal is given in the application drive software description. The drrtr element can generate different types of periodic messages supported by the drive communication protocol. The destination of the signal is selected by the drive signal. The drrtr element can also write parameters. In the normal phase, the overload of drrtr can be detected.The drrec (drive reciver) element is used to receive signals and control word values from the abb drive controller. The definitions of these signals are given in the application drive software description. The drrec element is just periodic information supported by the drive connection protocol. The receiving data source is selected by determining the drive signal and signal index through the element input parameters. The drrec element also has access to parameters, and overloads of drrec can be detected during configuration.
5417-028 From Woodward, USA
5501-432 WOODWARD Speed Sensor Full Series
5462-236 Controller debugger generator WOODWARD
5464-725 Controller debugger generator WOODWARD
3005-510 Generator Parts Speed Controller 2301A Speed
8200-015 WOODWARD generator set speed control board
5464-843 WOODWARD generator set speed control board
9907-624 WOODWARD 2301A Speed Control Controller
5466-419 WOODWARD generator set speed control board
5417-041 Generator Parts Speed Controller 2301A Speed
5462-292 WOODWARD Speed Sensor Full Series
8237-1245 WOODWARD 2301A Speed Control Controller
5421-112 WOODWARD generator set speed control board
8516-010 WOODWARD generator set speed control board
8915-948 WOODWARD 2301A Speed Control Controller
5462-966 Controller debugger generator WOODWARD
8440-2174 From Woodward, USA
8446-1068 WOODWARD generator set speed control board
5466-063 WOODWARD generator set speed control board
5464-843 Controller debugger generator WOODWARD
3462-757 WOODWARD 2301A Speed Control Controller
5460-840 Controller debugger generator WOODWARD
8444-1067 WOODWARD generator set speed control board
5464-538 WOODWARD generator set speed control board
5464-017 Controller debugger generator WOODWARD
8915-385 WOODWARD generator set speed control board
EGB-10P WOODWARD Speed Sensor Full Series
5462-117 Controller debugger generator WOODWARD
9907-994 Controller debugger generator WOODWARD
8272-684 Controller debugger generator WOODWARD
8239-002 WOODWARD 2301A Speed Control Controller
5464-332 WOODWARD Speed Sensor Full Series
9907-147 Generator Parts Speed Controller 2301A Speed
8440-1546 Controller debugger generator WOODWARD