1900-65A Bently State Monitoring Interface System

Product model: BENTLY 1900-65A
Working voltage: 24VDC

Working temperature: -40 ℃~85 ℃

Working humidity: 0~95%

Interface type: RS-485
BENTLY 1900-65A is a mechanical vibration monitoring system used to monitor the vibration level of rotating machinery. It can detect bearing vibration, mechanical imbalance, and other mechanical problems to ensure the normal operation of mechanical equipment

  • Email:sauldcsplc@outlook.com
  • Phone:+86 18350224834
  • WhatsApp:+8618350224834

Description

1900-65A Bently State Monitoring Interface System

1900-65A Product Introduction
  • BENTLY 1900-65A gateway is designed with multi protocol compatibility and modularity, seamlessly connecting industrial systems, 
  • operating at a wide temperature range of -40 ° C to 85 ° C, supporting 8-channel rotating equipment monitoring, 
  • remote configuration to improve efficiency, and ensuring stable power and automation.
1、 Product Overview
BENTLY 1900-65A is part of the Bently Nevada 3500 series monitoring system and is a communication gateway module designed specifically for industrial automation and process control applications.
It can connect the Bently Nevada 3500 system with other control systems or host computers to achieve data interconnectivity.
2、 Main characteristics
Communication interface: This module has rich communication interfaces and supports multiple communication protocols such as Ethernet, RS232, RS485, etc. It can be compatible with protocols such as Modbus and TCP/IP,
thus achieving integration with other industrial control systems.
input/output signal
Input signal: 0-10V DC, 4-20mA DC.
Output signal: 0-10V DC, 4-20mA DC.
Channel Count: Provides 8 analog input and 8 analog output channels to meet various monitoring and control requirements.
Working parameters:
Working voltage: 24VDC.
Working temperature range: -40 ° C to+85 ° C (some sources mention -30 ° C to+65 ° C or -40 ° C to+70 ° C, depending on the application environment).
Working humidity: 0% to 95%.
Remote configuration and management: Supports remote configuration and management functions, allowing for remote system settings and monitoring through the network, improving operational efficiency.
Modular design: Adopting a modular design, it is easy to install and maintain, reducing system downtime and maintenance costs.
High reliability and stability: After rigorous testing and validation, it ensures stable performance in various harsh environments, suitable for multiple fields such as industrial automation, process control, mechanical vibration monitoring and protection.
Contact Us
 
Mobile phone: 18350224834
 
E-mail: sauldcsplc@outlook.com
 
WhatsApp:+86 18350224834

Guoxin Yangdian ABB excitation regulator technology upgrade1 OverviewThe 2×630Mw coal-fired units (units #3 and #4) of Jiangsu Guoxin Yangzhou Power Generation Co., Ltd. were put into commercial operation in September 2006 and January 2007 respectively. The generator excitation system is a complete set of excitation system equipment imported from Switzerland provided by Shanghai ABB Engineering Co., Ltd. The supporting excitation system is ABBUnitrol5000. For more than 10 years of operation, jumper Hall elements have been disturbed and tripped, and ARCnet communication faults have tripped. and other problems, and as the use time increases, the failure rate increases significantly, and the stability of the excitation system gradually decreases. According to the needs of unit capacity increase, efficiency improvement and upgrading, the company has simultaneously upgraded the excitation system, upgraded the original Unitrol5000 to the latest Unitrol6800 system, and also adjusted the original components such as resistance-capacitance absorbers and jumpers. Make sure the parameters match.2 Advantages of the modified excitation system2.1 The reliability of the three-channel input power supply redundancy mode in the control part is improvedThe power supply of the control part adopts three input power supplies with AC or DC redundancy mode, thus improving the reliability of the system. Each control module is equipped with two independent power supplies for power supply, which significantly improves the redundancy of the power supply. In this way, the power supply of the control module can be disconnected separately to facilitate online replacement of faulty components. Secondly, since the boards are installed independently and each board is powered by dual power supplies, the power supply has an independent switch, making online maintenance work safer.2.2 Fiber optic redundant internal communicationsUnitrol6800 uses optical fiber redundancy for internal communication, which avoids the problem of downtime caused by ARCnet serial communication in the Unitrol5000 system. The controller can independently transmit the trigger pulse of the thyristor to the rectifier bridge. In conjunction with optical fiber transmission, the trigger pulse can be generated in each rectifier bridge, making the internal communication more resistant to interference.2.3 Eliminate the security risks brought by the public PSl board in the original system to the systemUnitrol6800 uses a rectifier cabinet to separately collect the synchronization voltage, excitation voltage and excitation current, which reduces the safety hazards caused by the public PsI board. In the rectifier bridge of Unitrol6800, the AC side phase sequence detection function is added. The fan power supply uses the independent power distribution method of each rectifier cabinet. The fan power supply loop control system of all rectifier cabinets is inside the rectifier cabinet, ensuring that each rectifier cabinet is It can independently control the fan in the cabinet, thereby solving the problem of power loss in the fan circuit of Unitrol5000 due to relay failure and avoiding non-stop accidents.In the rectifier bridge of the Unitrol5000 system, a Hall element is installed on the rectifier side to measure the excitation current of the rectifier bridge. The current sharing of the excitation current by the system must be carried out through a current sharing test. However, the characteristics of the Hall element itself prevent it from being based on the load. changes in dynamic current sharing. To this end, in the Unitrol6800 system, a CT is installed on the AC incoming line side of the rectifier cabinet to sample and calculate the excitation current. The linearity of the CT is very high, which ensures that the excitation system can perform dynamic current sharing according to the load changes of the working conditions, allowing Each rectifier cabinet of the system can be more balanced.In the rotor overvoltage protection of the Unitrol6800 system, a current relay is used to detect the current. Since the anti-interference ability of the current relay is stronger than the Hall element of the Unitrol5000, it can avoid false alarms of the rotor overvoltage in the excitation system caused by external interference and avoid power generation. The occurrence of unit non-stop accidents.3 Renovation PlanThe steam turbine generator unit has been modified to increase capacity and improve efficiency. The rated output of the steam turbine unit has been increased from 630Mw to 650Mw, the self-set rated current of the generator has been increased from 17495A to 19245A, and the rated voltage of the excitation rotor has also been increased from 400.1V to 428V. The excitation current increases from 4387.4A to 4697A. In this transformation, the cabinet structure of the excitation system remains unchanged. The system upgrade is achieved by upgrading boards, updating equipment and upgrading the control system. During the transformation process, it is necessary to ensure that the generator capacity is increased, and the excitation system needs to provide more excitation current and voltage to ensure the stable operation of the unit by increasing the deexcitation capacity.3.1 Adjustment of demagnetization and AC side voltage absorption moduleSince the generator is upgraded from 630Mw to 650Mw, the demagnetization and AC side overvoltage absorption modules need to be adjusted. For the adjustment of the capacity of the excitation de-excitation resistor, the capacity calculation of the de-excitation resistor needs to be calculated based on the most serious de-excitation state of the generator. The demagnetizing resistor is a siC nonlinear resistor. The number of resistors is changed from 5 to 6. The capacity of the demagnetizing resistor is 6MJ, which meets the needs of the excitation system for demagnetizing. In the modification of the demagnetization circuit jumper, the voltage resistance level of the thyristor was improved by replacing the jumper and BoD board. Regarding the transformation of the overvoltage absorption module on the AC side of the rectifier bridge, according to the design of the rectifier bridge of the ABB excitation system, the overvoltage absorption modules on the AC side of the rectifier bridge were changed to five groups in parallel.

3500/50M 288062-02 Transient Data Interface BENTLY
3500/22M 288055-01 Temperature monitor BENTLY
3500/42M 140734-02 BENTLY overspeed protection module
128276-01 BENTLY4 Channel Relay Module
3500/22-01-02-00 BENTLY vibration monitoring system
3500/93 135785-02 BENTLY overspeed protection module
3500/42 125672-02 Transient Data Interface BENTLY
1701/10-01 Temperature monitor BENTLY
3500/42 176449-02 Temperature monitor BENTLY
3500/22M 146031-01 BENTLY overspeed protection module
3500/22M 146031-01 BENTLY vibration monitoring system
3500/22M 146031-01 Transient Data Interface BENTLY
125680-01 BENTLY vibration monitoring system
3500/94 145988-01 BENTLY overspeed protection module
3500/42M 176449-02 BENTLY vibration monitoring system
135613-01-00 Temperature monitor BENTLY
3500/33-01-00 BENTLY vibration monitoring system
3500/92 136180-01 Temperature monitor BENTLY
3500/42M 176449-02 Transient Data Interface BENTLY
135613-01-00 Transient Data Interface BENTLY
3500/93  135785-01 BENTLY4 Channel Relay Module
3500/22-01-01 BENTLY vibration monitoring system
3500/15 125840-01 Transient Data Interface BENTLY
3500/92-02-01-01 BENTLY vibration monitoring system
167699-02 Temperature monitor BENTLY
3500/92 133323-01 BENTLY overspeed protection module
3500/33-01-00 BENTLY overspeed protection module
147663-01 BENTLY vibration monitoring system
3500/42M 140734-02 BENTLY vibration monitoring system
3500/22-01-01-00 138607-01 BENTLY vibration monitoring system
3500/22-01-01-00 138607-01 BENTLY4 Channel Relay Module
3500/42 176449-02 BENTLY overspeed protection module
3500/94 145988-01 BENTLY vibration monitoring system
3500/70-01-00 BENTLY4 Channel Relay Module
3500/22M BENTLY4 Channel Relay Module
3500/53 133388-01 Temperature monitor BENTLY
3500/62-04-01 BENTLY overspeed protection module
3500/42M-04-CN BENTLY vibration monitoring system
125840-01 Temperature monitor BENTLY
3500/22M 288055-01 Transient Data Interface BENTLY
60M500-05-00 Transient Data Interface BENTLY
3500/42M 176449-02 BENTLY vibration monitoring system
3500/22-01-01-00 BENTLY overspeed protection module
60M500-05-00 BENTLY overspeed protection module
3500/40M-01-00 BENTLY4 Channel Relay Module
3500/93  135785-01 BENTLY vibration monitoring system
3500/92-03-01 Temperature monitor BENTLY
3500/62-04-01 BENTLY4 Channel Relay Module